SPON Communications: Leading the Way in Innovative IP PA System Designs
SPON Communications: Leading the Way in Innovative IP PA System Designs
Blog Article
Network PA System for medium to massive tasks
Intro
The XC-9000 system is a completely electronic network PA system based on the TCP/IP protocol. By leveraging the TCP/IP protocol, the system guarantees the effective and right transmission of all information packets. Not just can it utilize existing computer networks, such as LANs or the Web, to transfer program signals, but also it can also be deployed on a committed broadcasting network.
A single-server system can support up to 3000 terminals and permits for web server cascading. There are no limitations on the concurrent broadcast networks, attaining true full digital broadcasting.
System Qualities
Adaptable PA System Layout
The PA system design is easy, including solution monitoring software, network microphones, network amplifiers, network audio speakers, and various other devices.All devices is connected through the TCP/IP intranet procedure, enabling for flexible configuration and very easy management of the system, with totally free control over broadcast web content, network gadgets, and areas with the network.
Comprehensive Sound Administration
The audio management software program includes integrated attributes for creating program plans, flexible zoning, and pre-scheduled broadcasts.It supports 24-hour shows, enabling changing setups during all day
Versatile Sound Source Assistance
The system supports numerous kinds of audio resources for sending alerts like live speech and BGM playback. Sound sources can originate from digital musical applications, CD/DVD players, microphones, and so on. On top of that, the system offers diverse functions of supporting various broadcasting attributes such as arranged broadcasting, zoned broadcasting, and emergency situation broadcasting.
Emergency Alarm System Integration
The system has an emergency alarm function and can be incorporated into an emergency alarm system. When the alarm main device gets the alarming signals, the cable will certainly transmit the signal to gadgets, which causes the XC-9000, sending out signals to audio speakers
Users might pick to preset settings to activate full-area or zoned alarm systems in emergencies. The alarm voices been available in multiple types and could be edited providing to demands. As an example, customers can change language setups, upload and edit their audio resources according to exact needs, such as intruding alarms, emergency alarm or air aid alarm systems, and so on
Emergency Alarm System Assimilation
The system has an emergency alarm feature and can be incorporated into a fire alarm system. When the alarm central system gets the startling signals, the cable will transfer the signal to gadgets, which activates the XC-9000, sending out signals to audio speakers
Users could choose to preset settings to activate full-area or zoned alarms in emergencies. The alarm voices come in several types and might be edited catering to requirements. As an example, individuals can change language setups, upload and modify their audio resources according to precise demands, such as intruding alarms, emergency alarm or air aid alarms, etc
App Control for System Workflow
The system allows mobile app login and use, allowing customers to initiate broadcasts and various other procedures to accredited terminals through the server software, ensuring a structured and convenient experience.
Integrated SIP Compatibility
The system not just enables SIP phones to visit, however also can be attached to third-party SIP web server or IPPBX, which establishes a completely incorporated and compatible interaction system through smooth combination right into existing systems.
Open SDK
When large project like clever park takes place, the system offers an open SDK incorporated into third-party application platforms - IP Paging Microphone
System Framework
Key Functions
Set up Playback
The system is able to automatically transmit according to the set up jobs as long as individuals upload the audio declare each time period of the day to the web server and create a playback routine.
Area Broadcasting
The system can arbitrarily separate a few network gadgets into various zones to play specified audio programs or send announcements to any marked area. The quantity of each tool can be remotely readjusted.
Real-time Broadcasting
The system can transmit and record radio programs or various other exterior audio sources in real-time, and at the exact same time relayed them in sync.
Smoke Alarm Assimilation
The system can be integrated with the fire alarm system for control. When a fire alarm signal is activated, it instantly activates the emergency broadcast feature and sustains surrounding floor alarms. It also permits manual emergency broadcasting by clicking a single switch.
SIP Phone Combination
The system can be incorporated with SIP servers, enabling real-time speech of voice broadcasting via SIP phones to send statements anytime and anywhere.
CCTV Assimilation
The electronic devices such as IP POE Speakers adopts the international standard ONVIF method, which allows their voices to be transmitted using VMS platforms. The terminals can additionally be integrated with CCTV systems for synchronized broadcast.
Key Products
Sound Management Software Application XC-9000
B/S design, supports cross-platform applications.
Covers typical broadcasting system operates, enabling dividing monitoring.
Unified monitoring of terminals within the system, seeing work condition, and set quantity adjustment, etc.
Sustains structure multi-level web server designs, deploying management according to individual geographical regions.
Provides SDK growth packages for additional advancement and combination with other system platforms.
Network Paging Console XC-9038N
Power: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Interaction Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Reaction: 100Hz~ 16KHz.
Operating Temperature level: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.
Network Paging Console XC-9037N
Power Supply: DC12V/1.5 A.
Present: 4-inch touchscreen, resolution 480 * 480.
Communication Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Regularity Action: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.
Network Horn Speaker GEN-6391A03
Power Supply: DC24V/2.7 A or POE.
Interaction Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Intercom: Sustained, Built-in Microphone.
Running Temperature: -20~ 50 ℃.
Measurements: 283.1 * 224.3 * 269mm.
Network Ceiling Audio Speaker GEN-6211A03
Power Supply: DC 24V/1A or POE.
Communication Protocols: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Response: 100Hz~ 18KHz.
Running Temperature: -20 to 50 ° C.
Capacities: φ213 x 165mm.
Network Wall Mount Speaker GEN-6011A03
Power Supply: DC24V/1A go to the website or POE.
Interaction Procedure: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Regularity Response: 100Hz~ 18KHz.
Running Temperature: -20~ 50 ℃.
Measurements: 193x151.5 x292mm.
Network Column Speaker GEN-6191A03
Power Supply: DC24V/1A or POE.
Communication Procedure: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 90dB.
Regularity Action: 45Hz~ 18KHz.
Operating Temperature level: -10~ 55 ℃.
Dimensions: 296x140x130mm.
Network Sound Bridge GEN-3101A01
Power Supply: POE.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 85dB.
Regularity Response: 50Hz~ 20KHz.
Operating Temperature level: -10~ 55 ℃.
Measurements: 126x66x27mm.
Network Digital Amplifier XC-9508P
Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Interaction Protocol: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Action: 60Hz~ 18KHz.
Operating Temperature: -10~ 50 ℃.
Measurements: 440x300x44mm.
Zone Mixing Digital Amplifier NBS-2301
Power Supply : AC 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Interaction Protocol : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Proportion :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Regularity Action :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Running Temperature :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.
IP User Interface Unit NAC-5003
Power Supply: AC100V~ 240V, 50/60Hz.
Communication Method: TCP/IP, UDP.
User interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm outcomes.
Running Temperature level: -10~ 50 ℃.
Dimensions: 483x259x44mm.
Option For College
Versatile Zoning Broadcast:
The completely network terminals can recognize versatile zoning options, permitting broadcasting notices to different areas or specific terminals ( tools).
Institution Bell System:
It Visit This Link supplies college bell system at the beginning/ending of the class - IP Paging Microphone. Numerous scenarios can be designed, including various set up program tasks according to summer/winter schedule
Emergency Alarm Combination
It sustains integration with fire alarm systems, enabling fire alarm signals to be integrated right into the PA system.
Classroom Sound Boosting
Terminals support daily applications in class scenes. They can be connected to projectors or interactive whiteboard for audio amplification.
Smart Street Lamp/Security Post
Support SIP Method:
Integrated SIP procedure for smooth combination with network communication systems.
VMS Operatings Systems Assimilation:
Integrated ONVIF method for integration with VMS systems.
Third-Party Combination:
Constructed In HTTP API for assimilation with third celebration platforms.
Voice Alarm System Setting Off:
Integrated in alarm system input interface for setting off voice alarm systems with video cameras.
Option For Resort
Zone Control by Flooring:
The system supplies complete network settings, splitting areas counting on different floors and control over each zone independently.
Emergency Alarm Combination:
The system can be integrated with emergency alarm system, enabling integration of fire alarm system signals right into the broadcasting system.
Scheduled Broadcasting:
It supports programmable arranged broadcasting, permitting versatile setups according to various requirements.
Emergency situation Broadcasting:
It supports emergency situation broadcasting for the entire location, making it possible for one-click emergency situation interaction.
Option For Manufacturing facility
Area Broadcasting:
It allows relaying to any kind of zone, assuring no disturbance between different areas.
Alarm system Triggering:
Terminals have numerous type of interfaces, allowing to cause alarms when connected with cams.
All Network Devices:
Implementation of totally network devices considerably lowers the problem of operating such as inspecting devices on hazardous sites, and hence securing individuals and residential property.
The deployment of all network tools significantly lowers the difficulty of operation and upkeep management
Integrated SIP Phones:
The system can be incorporated with SIP phone and program notifications using SIP phones at any moment and anywhere. Two-way sound talkback between SIP phones and IP POE Speakers makes it easy for you can look here checking tools resting in workplace or other workplaces.
The XC-9000 system is a fully digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP protocol, the system makes sure the reliable and appropriate transmission of all information packages. The system supports numerous types of audio resources for sending out notices like live speech and BGM playback. In addition, the system supplies diverse functions of sustaining various broadcasting functions such as scheduled broadcasting, zoned broadcasting, and emergency broadcasting.
The system can be integrated with the fire alarm system for control.
Report this page